欢迎来到MSDS查询网--MSDS安全网
当前位置:MSDS安全网 -> 英文MSDS查询 -> WIA HARDCORE TIC MSDS报告
免费英文MSDS查询网站--MSDS安全网
WIA HARDCORE TIC MSDS报告[下载][中文版]

Section 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NAME

WIA HARDCORE TIC

NFPA

Flammability 0
Toxicity 2
Body Contact 2
Reactivity 0
Chronic 2
SCALE: Min/Nil=0 Low=1 Moderate=2 High=3 Extreme=4

PRODUCT USE

Consumable self shielded or open arc tubular hard- facing wire depositing finely dispersed
titanium carbides in a high chromium martensitic matrix. Being self shielded, external
shielding gas is eliminated for outdoor applications such as crusher hammers, rolls,
tampers, scraper blades, bucket teeth, bulldozer blades, etc. The weld metal resists
extreme abrasion and heavy impact. Two layers give a deposit hardness of 54- 56 HRc.

SYNONYMS

"Product number 225024S", W.I.A., "Welding Industries of Australia", FCAW, "welding
electrode", "titanium carbide hardfacing", "self-shielding hard-surfacing and rebuilding
wire", "martensitic hard-facing wire"

Section 2 - HAZARDS IDENTIFICATION

CANADIAN WHMIS SYMBOLS

EMERGENCY OVERVIEW

RISK

POTENTIAL HEALTH EFFECTS

ACUTE HEALTH EFFECTS

SWALLOWED

  Although ingestion is not thought to produce harmful effects, the material may still be damaging to the health of the individual following ingestion, especially where pre-  existing organ (e.g. liver, kidney) damage is evident. Present definitions of harmful or toxic substances are generally based on doses producing mortality (death) rather than those producing morbidity (disease, ill-health). Gastrointestinal tract discomfort may produce nausea and vomiting. In an occupational setting however, ingestion of insignificant quantities is not thought to be cause for concern.  Not normally a hazard due to physical form of product.  Considered an unlikely route of entry in commercial/industrial environments.  

EYE

  Although the material is not thought to be an irritant, direct contact with the eye may produce transient discomfort characterized by tearing or conjunctival redness (as with windburn).  Fumes from welding/brazing operations may be irritating to the eyes.  

SKIN

  The material is not thought to produce adverse health effects or skin irritation following contact (as classified using animal models). Nevertheless, good hygiene practice requires that exposure be kept to a minimum and that suitable gloves be used in an occupational setting.  Chrome fume, as the chrome VI oxide, is corrosive to the skin and may aggravate pre-  existing skin conditions such as dermatitis and eczema. As a potential skin sensitizer, the fume may cause dermatoses to appear suddenly and without warning. Absorption of chrome VI compounds through the skin can cause systemic poisoning effecting the kidneys and liver.  

INHALED

  Inhalation may produce health damage*.  The material is not thought to produce respiratory irritation (as classified using animal models). Nevertheless inhalation of the material, especially for prolonged periods, may produce respiratory discomfort and occasionally, distress.  Chrome fume is irritating to the respiratory tract and lungs. Toxic effects result from over-exposure. Asthmatic conditions may result as a consequence of the sensitising action of chrome VI compounds.  Manganese fume is toxic and produces nervous system effects characterized by tiredness. Acute poisoning is rare although acute inflammation of the lungs may occur. A chemical pneumonia may also result from frequent exposure. Inhalation of freshly formed metal oxide particles sized below 1.5 microns and generally between 0.02 to 0.05 microns may result in "metal fume fever". Symptoms may be delayed for up to 12 hours and begin with the sudden onset of thirst, and a sweet, metallic or foul taste in the mouth. Other symptoms include upper respiratory tract irritation accompanied by coughing and a dryness of the mucous membranes, lassitude and a generalized feeling of malaise. Mild to severe headache, nausea, occasional vomiting, fever or chills, exaggerated mental activity, profuse sweating, diarrhea, excessive urination and prostration may also occur. Tolerance to the fumes develops rapidly, but is quickly lost. All symptoms usually subside within 24-36 hours following removal from exposure.  Persons with impaired respiratory function, airway diseases and conditions such as emphysema or chronic bronchitis, may incur further disability if excessive concentrations of particulate are inhaled.  

CHRONIC HEALTH EFFECTS

  Principal route of exposure is inhalation of welding fumes from electrodes and workpiece. Reaction products arising from electrode core and flux appear as welding fume depending on welding conditions, relative volatilities of metal oxides and any coatings on the workpiece. Studies of lung cancer among welders indicate that they may experience a 30-  40% increased risk compared to the general population. Since smoking and exposure to other cancer-causing agents, such as asbestos fibre, may influence these results, it is not clear whether welding, in fact, represents a significant lung cancer risk. Whilst mild steel welding represents little risk, the stainless steel welder, exposed to chromium and nickel fume, may be at risk and it is this factor which may account for the overall increase in lung cancer incidence among welders. Cold isolated electrodes are relatively harmless.  Welding fume with high levels of ferrous materials may lead to particle deposition in the lungs (siderosis) after long exposure. This clears up when exposure stops. Chronic exposure to iron dusts may lead to eye disorders.  severe disorders of the nervous system, has been reported in welders working on Mn steels in confined spaces.  Exposure to fume containing high concentrations of water-soluble chromium (VI) during the welding of stainless steels in confined spaces has been reported to result in chronic chrome intoxication, dermatitis and asthma. Certain insoluble chromium (VI) compounds have been named as carcinogens (by the ACGIH) in other work environments. Chromium may also appear in welding fumes as Cr2O3 or double oxides with iron. These chromium (III) compounds are generally biologically inert.  Other welding process exposures can arise from radiant energy UV flash burns, thermal burns or electric shockThe welding arc emits ultraviolet radiation at wavelengths that have the potential to produce skin tumours in animals and in over-exposed individuals, however, no confirmatory studies of this effect in welders have been reported.  
【温馨提示】 MSDS安全网为了能让广大网友得到更好的服务,杜绝不法人员盗用本站共享资源,最终决定隐藏部分核心资源内容,只供注册会员查看; 本站会员采用微信账号登录/免费注册机制,登录成功后即可免费查看和下载本站所有资源!谢谢支持! 微信账号登录 注意:微信账号登录成功后,若页面没有刷新,请按F5刷新本页面!
在线下载 WIA HARDCORE TIC MSDS报告

热门关键字

MSDS常识

中文MSDS报告

英文MSDS报告

标准下载

化工字典CAS