Section 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NAME

WATTYL EUROCLEAR MS1000 (PACK A)

NFPA

Flammability 3
Toxicity 2
Body Contact 2
Reactivity 1
Chronic 2
SCALE: Min/Nil=0 Low=1 Moderate=2 High=3 Extreme=4

PRODUCT USE

Part A or Base of a 2 pack acrylic urethane coating system. Requires that the two parts be
mixed by hand or mixer before use, in accordance with manufacturers directions. Mix only
as much as is required. Do not return the mixed material to the original containers.
Application is usually by spray atomisation in a ventilated spray booth, after viscosity
reduction with thinner. The material when ready for use, i.e. with 2 parts mixed together,
CONTAINS free organic isocyanate. Application requires control measures, special
precautions and use of personal protective gear. [APMF]. Refer also to protective measures
for the other component used with the product. Read both MSDS before using; store and
attach MSDS together.

SYNONYMS

"acrylic urethane polyurethane two pack paint varnish Base"

Section 2 - HAZARDS IDENTIFICATION

CANADIAN WHMIS SYMBOLS

EMERGENCY OVERVIEW

RISK

Harmful by inhalation.
Irritating to eyes.
HARMFUL - May cause lung damage if swallowed.
Highly flammable.
Repeated exposure may cause skin dryness and cracking.
Vapors may cause dizziness or suffocation.

POTENTIAL HEALTH EFFECTS

ACUTE HEALTH EFFECTS

SWALLOWED

  Although ingestion is not thought to produce harmful effects, the material may still be damaging to the health of the individual following ingestion, especially where pre-  existing organ (e.g. liver, kidney) damage is evident. Present definitions of harmful or toxic substances are generally based on doses producing mortality (death) rather than those producing morbidity (disease, ill-health). Gastrointestinal tract discomfort may produce nausea and vomiting. In an occupational setting however, ingestion of insignificant quantities is not thought to be cause for concern.  Not a likely route of entry into the body in commercial or industrial environments. The liquid may produce considerable gastrointestinal discomfort and be harmful or toxic if swallowed. Ingestion may cause nausea, pain and vomiting. Vomit entering the lungs by aspiration can cause inflammation of the lungs, which can lead to death.  

EYE

  This material can cause eye irritation and damage in some persons.  The vapour when concentrated has pronounced eye irritation effects and this gives some warning of high vapour concentrations. If eye irritation occurs seek to reduce exposure with available control measures, or evacuate area.  The material may produce severe irritation to the eye causing pronounced inflammation. Repeated or prolonged exposure to irritants may produce conjunctivitis.  

SKIN

  Skin contact with the material may damage the health of the individual; systemic effects may result following absorption.  The material is not thought to be a skin irritant (as classified using animal models). Temporary discomfort, however, may result from prolonged dermal exposures. Good hygiene practice requires that exposure be kept to a minimum and that suitable gloves be used in an occupational setting.  Toxic effects may result from skin absorption.  The material may cause skin irritation after prolonged or repeated exposure and may produce on contact skin redness, swelling, the production of vesicles, scaling and thickening of the skin.  

INHALED

  There is some evidence to suggest that this material, if inhaled, can irritate the throat and lungs of some persons.  Inhalation hazard is increased at higher temperatures.  Isocyanate vapors are irritating to the airways and can cause their inflammation, with wheezing, gasping, severe distress, even loss of consciousness and fluid in the lungs. Nervous system symptoms that may occur include headache, sleep disturbance, euphoria, inco-ordination, anxiety, depression and paranoia. Digestive effects include nausea and vomiting. Breathing difficulties may occur unpredictably after a period of tolerance and after skin contact. Allergic inflammation of the skin can occur, with rash, itching, blistering, and swelling of the hands and feet. Sensitive people can react to very low levels and should not be exposed to this material.  Sensitization reactions may appear suddenly after repeatedsymptom free exposures.  Inhalation of vapor may aggravate a pre-existing respiratory condition.  Inhalation of high concentrations of gas/vapor causes lung irritation with coughing and nausea, central nervous depression with headache and dizziness, slowing of reflexes, fatigue and inco-ordination.  If exposure to highly concentrated solvent atmosphere is prolonged this may lead to narcosis, unconsciousness, even coma and possible death.  

CHRONIC HEALTH EFFECTS

  There is some evidence that inhaling this product is more likely to cause a sensitization reaction in some persons compared to the general population.  
  Principal routes of exposure are usually by inhalation of vapor and skin contact/absorption.  Chronic solvent inhalation exposures may result in nervous system impairment and liver and blood changes. [PATTYS].  Prolonged or continuous skin contact with the liquid may cause defatting with drying, cracking, irritation and dermatitis following.  Persons with a history of asthma or other respiratory problems or are known to be sensitised, should not be engaged in any work involving the handling of isocyanates. [CCTRADE-Bayer, APMF].  As with any chemical product, contact with unprotected bare skin; inhalation of vapor, mist or dust in work place atmosphere; or ingestion in any form, should be avoided by observing good occupational work practice.  