WATTYL SIGMACOVER DTM 800 PART B
Flammability | 1 | |
Toxicity | 2 | |
Body Contact | 2 | |
Reactivity | 1 | |
Chronic | 2 | |
SCALE: Min/Nil=0 Low=1 Moderate=2 High=3 Extreme=4 |
Requires that the two parts be mixed by hand or mixer before use, in accordance with
manufacturers directions. Mix only as much as is required. Do not return the mixed
material to the original containers. Used according to manufacturer' s directions. The use
of a quantity of material in an unventilated or confined space may result in increased
exposure and an irritating atmosphere developing. Part B of a two- part epoxy coating
system.
"epoxy coating"
May cause SENSITIZATION by skin contact.
Harmful by inhalation, in contact with skin and if swallowed.
Irritating to eyes and skin.
Toxic to aquatic organisms, may cause long- term adverse effects in the aquatic
environment.
Accidental ingestion of the material may be damaging to the health of the individual.
There is some evidence to suggest that this material can causeeye irritation and damage in some persons. The material may produce moderate eye irritation leading to inflammation. Repeated or prolonged exposure to irritants may produce conjunctivitis.
Skin contact with the material may be harmful; systemic effects may resultfollowing absorption. This material can cause inflammation of the skin oncontact in some persons. The material may accentuate any pre-existing dermatitis condition. Entry into the blood-stream, through, for example, cuts, abrasions or lesions, may produce systemic injury with harmful effects. Examine the skin prior to the use of the material and ensure that any external damage is suitably protected. The material may cause skin irritation after prolonged or repeated exposure and may produce on contact skin redness, swelling, the production of vesicles, scaling and thickening of the skin.
Inhalation of vapors or aerosols (mists, fumes), generated by the material during the course of normal handling, may be harmful.
There is some evidence that inhaling this product is more likely to cause a sensitization reaction in some persons compared to the general population. Skin contact with the material is more likely to cause a sensitization reaction in some persons compared to the general population. Bisphenol A may have effects similar to female sex hormones and when administered to pregnant women, may damage the fetus. It may also damage male reproductive organs and sperm. Sensitization may give severe responses to very low levels of exposure, i.e. hypersensitivity. Sensitized persons should not be allowed to work in situations where exposure may occur.