Section 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NAME

WATTYL PLAKKAR HARDENER 908-00194

NFPA

Flammability 1
Toxicity 2
Body Contact 2
Reactivity 3
Chronic 2
SCALE: Min/Nil=0 Low=1 Moderate=2 High=3 Extreme=4

PRODUCT USE

Used as a hardener in polyester filler, polyester putty, polyester adhesive. Normally
added to polyester filler (putty) at rates between 1 part hardener to 100 parts filler
(1%) and 1 part hardener to 33 parts filler (3%). Addition of larger amounts may increase
harzard by causing too rapid solidification of filler with evolution of styrene vapour
resulting from high exotherm (heat generation). Use only as directed by manufacturer.

Section 2 - HAZARDS IDENTIFICATION

CANADIAN WHMIS SYMBOLS

EMERGENCY OVERVIEW

RISK

Risk of explosion by shock, friction, fire or other sources of ignition.
Contact with combustible material may cause fire.
Irritating to eyes.
May cause SENSITIZATION by skin contact.

POTENTIAL HEALTH EFFECTS

ACUTE HEALTH EFFECTS

SWALLOWED

  Ingestion of organic peroxides may produce nausea, vomiting, abnormal pain, stupor, bluish discoloration of skin and mucous membranes. Inflammation of the heart muscle may also occur.  

EYE

  Evidence exists, or practical experience predicts, that the material may cause eye irritation in a substantial number of individuals. Prolonged eye contact may cause inflammation characterized by a temporary redness of the conjunctiva (similar to windburn).  Eye contact with organic peroxides can cause clouding, redness, swelling and burns of the eye on prolonged contact.  

SKIN

  Skin contact with the material may damage the health of the individual; systemic effects may result following absorption.  There is some evidence to suggest that the material may cause mild but significant inflammation of the skin either following direct contact or after a delay of some time. Repeated exposure can cause contact dermatitis which is characterized by redness, swelling and blistering.  All organic peroxides are irritating to the skin and if allowed to remain on the skin, may produce inflammation; some are allergenic.  Entry into the blood-stream, through, for example, cuts, abrasions or lesions, may produce systemic injury with harmful effects. Examine the skin prior to the use of the material and ensure that any external damage is suitably protected.  

INHALED

  Inhalation hazard is increased at higher temperatures.  The inhalation of organic peroxide dusts or vapors can produce throat and lung irritation and cause an asthma-like effect. Over-exposure can cause tears, salivation, lethargy, slow breathing, breathing difficulties, headache, weakness, tremor, stupor and swelling of the lung.  There is some evidence to suggest that the material can cause respiratory irritation in some persons. The body's response to such irritation can cause further lung damage.  

CHRONIC HEALTH EFFECTS

  Skin contact with the material is more likely to cause a sensitization reaction in some persons compared to the general population.  There has been some concern that this material can cause cancer or mutations but there is not enough data to make an assessment.  Limited evidence suggests that repeated or long-term occupational exposure may produce cumulative health effects involving organs or biochemical systems.  There is some evidence that inhaling this product is more likely to cause a sensitization reaction in some persons compared to the general population.  Persistent exposure over a long period of time to peroxides produces allergic skin reactions ( redness and scaling of the skin ) and asthmatic wheezing.  