欢迎来到MSDS查询网--MSDS安全网
当前位置:MSDS安全网 -> 英文MSDS查询 -> K-Y BRAND ULTRA GEL MSDS报告
免费英文MSDS查询网站--MSDS安全网
K-Y BRAND ULTRA GEL MSDS报告[下载][中文版]

Section 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NAME

K-Y BRAND ULTRA GEL

NFPA

Flammability 0
Toxicity 2
Body Contact 1
Reactivity 0
Chronic 2
SCALE: Min/Nil=0 Low=1 Moderate=2 High=3 Extreme=4

PRODUCT USE

External.

Section 2 - HAZARDS IDENTIFICATION

CANADIAN WHMIS SYMBOLS

EMERGENCY OVERVIEW

RISK

POTENTIAL HEALTH EFFECTS

ACUTE HEALTH EFFECTS

SWALLOWED

  Accidental ingestion of the material may be damaging to the health of the individual.  Central nervous system (CNS) depression may include general discomfort, symptoms of giddiness, headache, dizziness, nausea, anaesthetic effects, slowed reaction time, slurred speech and may progress to unconsciousness. Serious poisonings may result in respiratory depression and may be fatal.  Ingestion of propylene glycol produced reversible central nervous system depression in humans following ingestion of 60 ml. Symptoms included increased heart-rate (tachycardia),  excessive sweating (diaphoresis) and grand mal seizures in a 15 month child who ingested large doses (7.5 ml/day for 8 days) as an ingredient of vitamin preparation.  Excessive repeated ingestions may cause hypoglycaemia (low levels of glucose in the blood stream) among susceptible individuals; this may result in muscular weakness, incoordination and mental confusion.  Very high doses given during feeding studies to rats and dogs produce central nervous system depression (although one-third of that produced by ethanol), haemolysis and insignificant kidney changes.  In humans propylene glycol is partly excreted unchanged in the urine and partly metabolised as lactic and pyruvic acid. Lactic acidosis may result.  

EYE

  There is some evidence to suggest that this material can causeeye irritation and damage in some persons.  Although the liquid is not thought to be an irritant, direct contact with the eye may produce transient discomfort characterized by tearing or conjunctival redness (as with windburn).  

SKIN

  The material is not thought to produce adverse health effects or skin irritation following contact (as classified using animal models). Nevertheless, good hygiene practice requires that exposure be kept to a minimum and that suitable gloves be used in an occupational setting.  Entry into the blood-stream, through, for example, cuts, abrasions or lesions, may produce systemic injury with harmful effects. Examine the skin prior to the use of the material and ensure that any external damage is suitably protected.  

INHALED

  Inhalation may produce health damage*.  Not normally a hazard due to non-volatile nature of product.  The material is not thought to produce either adverse health effects or irritation of the respiratory tract following inhalation (as classified using animal models). Nevertheless, adverse effects have been produced following exposure of animals by at least one other route and good hygiene practice requires that exposure be kept to a minimum and that suitable control measures be used in an occupational setting.  

CHRONIC HEALTH EFFECTS

  There is some evidence that inhaling this product is more likely to cause a sensitization reaction in some persons compared to the general population.  
  There is limited evidence that, skin contact with this product is more likely to cause a sensitization reaction in some persons compared to the general population.  Propylene glycol is though, by some, to be a sensitizing principal following the regular use of topical creams by eczema patients. A study of 866 persons using a formulation containing propylene glycol in a patch test indicated that propylene glycol caused primary irritation in 16% of exposed individuals probably caused by dehydration. Undiluted propylene glycol was tested on 1556 persons in a 24 hour patch test. 12.5% showed reactions which were largely toxic (70%) or allergic in nature (30%). Reaction responses reached their maximum on the second day or later. Reactions were seasonal in nature ranging from 17.8% in winter to 9.2% in other seasons. In a patch-test using 25 standard allergens conducted on 500 individuals, propylene glycol ranked fourth in sensitizing response. 84 subjects were patch tested using 100% propylene glycol. as well as 2% and 5% in water. With undiluted material, 15% demonstrated a reaction, with 40% of the reactions being allergic in nature and 60% being irritant. In dilute solutions 5 of 248 subjects exhibited a reaction.  Undiluted propylene glycol tested on the skin of man produced no irritation under open conditions but when applied under occlusive conditions, for 2 weeks, it produced severe erythema, edema and vesicles, probably due to sweat retention and weak primary irritation.  Predictive contact skin sensitization tests indicate that propylene glycol is an intermediate grade sensitizer with an index of 1% of tested subjects.  Groups of cats fed 5 gm/kg/day of propylene glycol for 14 weeks showed a significant dose-  related increase in red blood cell Heinz body formation without any marked signs of hemolytic anemia. The no-effect-level for cats without formation of Heinz bodies is 100-  500 ml/kg. There is no evidence of anemia or degenerative change. Groups of rats dosed orally with 0.5 or 10 mg/kg/day for 12 weeks had lowered food intake but no adverse effects on body weights. Erythrocytes were more fragile. Heinz bodies were not apparent.  Sensitization may result in allergic dermatitis responses includingrash, itching, hives or swelling of extremities.  Sensitization may give severe responses to very low levels of exposure, i.e. hypersensitivity. Sensitized persons should not be allowed to work in situations where exposure may occur.  
【温馨提示】 MSDS安全网为了能让广大网友得到更好的服务,杜绝不法人员盗用本站共享资源,最终决定隐藏部分核心资源内容,只供注册会员查看; 本站会员采用微信账号登录/免费注册机制,登录成功后即可免费查看和下载本站所有资源!谢谢支持! 微信账号登录 注意:微信账号登录成功后,若页面没有刷新,请按F5刷新本页面!
在线下载 K-Y BRAND ULTRA GEL MSDS报告

热门关键字

MSDS常识

中文MSDS报告

英文MSDS报告

标准下载

化工字典CAS